Detailed specifications BM14G4
| Accuracy class | OIML R60 C3 | OIML R60 C4 | |||
| Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.02 | |||
| Maximum capacity ( Emax ) | t | 10, 20, 30, 40, 50 | |||
| Max.number of load cell intervals | nLC | 3000 | 4000 | ||
| Ratio of min. LC verification interval | Y = Emax / vmin | 8800 | |||
| Combined Error | %FS | ≤± 0.0230 | ≤± 0.0175 | ||
| Minimum dead load | Of Emax | 0% | |||
| Safe overload | of Emax | 150 % | |||
| Ultimate overload | of Emax | 300 % | |||
| Zero balance | of FS | < ± 1.0 % | |||
| Excitation, recommended voltage | V | 5 ~ 12 | |||
| Excitation maximum | V | 18 | |||
| Input resistance | Ω | 700 ± 7 | |||
| Output resistance | Ω | 700 ± 7 | |||
| Insulation resistance | MΩ | ≥5000 ( at 50VDC ) | |||
| Compensated temperature | °C | -10 ~+40 | |||
| Operating temperature | °C | -35 ~ +65 | |||
| Storage temperature | °C | -40 ~ +70 | |||
| Element material | Stainless steel | ||||
| Ingress Protection (acc. to EN 60529) | IP68 | ||||
| Recommended torque on fixation | Nm | - | |||
| ATEX classification (optional) | II1G Ex ia II1C T4 | II1D Ex iaD 20 T73°C | II3G nL IIC T4 | ||